Control with Precision

Deliver pinpoint precise hot water temperatures  throughout entire facilities, maintaining a consistent  ±2°F range under dynamic load conditions.
is2-sanitize-closeup

Automate Maintenance 

Eliminate manual adjustments, optimize system  performance, and strengthen safety and compliance with auto-balancing and automated sanitation functionality. 
IS2-nexa-install

Monitor from Anywhere

Access real-time system data, view historical  data, and make remote  adjustments through  Nexa™, all backed by a 5-year warranty. 
IS2-WP-mockup

WHITE PAPER

Switch to Smarter Water Tempering


Traditional thermostatic mixing valves can drift by ±7°F, creating unpredictable temperature swings that increase the risk of scalding and legionella growth. With legionella capable of multiplying into trillions of bacteria in just one week, and scald injuries accounting for 34% of all U.S. burn cases, temperature instability is a serious liability. Discover how digital mixing delivers ±2°F precision, faster response to demand changes, and real‑time system insight that empowers facilities to protect occupants, reduce risk, and improve energy efficiency.

Temper Water. Not Expectations. 

Empower users with remote tempering insight and control, ensuring 24/7 scalding and waterborne bacteria protections.

IS2-DMV-blog-thumb

Integrated inlet check valves to prevent cross flow
Programmable alerts with time stamped history
Programmable temperature setback schedule
Valve flows full cold for safety if power fails  
Connect by BAS or by Wi-Fi /Ethernet connection to Nexa 
Natively supports BACnet MS/TP and Modbus protocols

6 Game-Changing Reasons Facilities Are Switching to Digital Mixing 

Highly Precise Temperature Control

Traditional TMVs have a temperature range of 7°F and drift over time, potentially creating conditions for scalding or legionella growth. Digital mixing delivers +2°F accuracy even when demand swings.

Real-Time Insight for Confident System Management

Without real-time monitoring, alerts, logs, or historical data, hot water systems with traditional TMVs can operate out of compliance long before crews catch on. Digital valves track system conditions constantly, so any deviation triggers an immediate response.

Automated Sanitation Protects Against Waterborne Bacteria

Manual or incomplete sanitization creates an elevated Legionella risk. Digital systems automate high-temp cycles and verify they ran correctly, closing a critical safety loop.

Seamless Connectivity for Smarter Buildings

A TMV can't talk to your building automation system, leaving your team in the dark. Digital valves connect with BACnet, Modbus, Wi‑Fi, and Nexa™, giving engineers full remote visibility from anywhere, any time.

Built-In Failsafe State

Traditional TMVs can't prevent scalding during power outages. Digital mixing defaults to full cold on power loss, protecting occupants against uncontrolled hot water exposure.

Predictive Maintenance that Reduces Downtime

Traditional TMVs rely on periodic manual checks and reactive maintenance. Digital mixing systems provide logs, diagnostics, and performance data, helping facilities address issues proactively instead of after failures occur.

The Benchmark in Digital Mixing

The IntelliStation 2 sets the standard for smart, reliable hot water control. 

Features IntelliStation® 2 Competitor Valves
Minimum Flow Rate 3 GPM (3/4") to 5 GPM (2") 3 GPM (3/4") to 12 GPM (2")
Temperature Range 60°F - 180°F 95°F - 160°F
Body Material Brass (Stainless Steel Coming Soon) Stainless Steel or Bronze
Smart & Connected BACnet MS/TP & IP, Modbus RTU & IP, WiFi, Ethernet, Nexa TM BACnet MSTP, Modbus RTU, WiFi
Warranty 5 years with NexaTM 1 year
Sensors Shipped with 1 Temp sensor, can add 4 T/P sensors Shipped with 1 Temp sensor, 3 added later


Digital Mixing Savings Calculator

Estimate the difference in energy cost (in energy units and dollars) required to heat water to desired settings between the IntelliStation and an equivalent TMV. 

  • Calculate the energy required to raise recirculation water temperature from the lowest end of the temperature control range to the outlet and water heater temperatures
  • Provides a high-level estimate of savings gained by better temperature control and lower circulated temperature during non-use hours. Greater savings can be calculated using the broader calculation tool that allows for separate water heater/outlet temperature settings for the DMV/TMV valve types.


1.
Select your heat source, energy cost, and temperature settings
Note:
You can add a custom rate for your location.
Use units that match the energy type of the selected heat source: therm or kWh
Price: ($)
Flow Rate

Allowable Temperature Fluctuation
5-40 GPM ±5°F
Over 40 GPM ±7°F
  TMV temperature control variation +/-°F
 
2 3 4 5 6 7
Note:
The Water Heater Tank Temperature should be a minimum of 10 degrees higher than the Outlet Temperature. This value + setback hours are used to calculate total savings.
Outlet temp. Water heater tank temp.
 
120 130 140 150 160 170

Return Temperature


TMV
DMV
108°F
108°F
2.
Select your TMV system and preferred setback settings
Equivalent DMV system:


intellistation2 IntelliStation 2
Interpretation:
Setback = 140°F Outlet Temp – 20°F.
Setback = 120°F for 14 hrs on Saturday
and 14 hrs on Sunday

Save with Setback Hours
Select normal hours of operation per day
Mon-Fri
Saturday
Sunday
Setback - Temperature reduced by:
 
 
3.

Get results
Savings Summary
  TMV vs DMV
+/-2°F Temp Control
Setback

Monthly:
0
0
Annual:
0
0
Total Savings
Monthly Savings: 0
Energy Monthly Savings: 0aaa
Annual Savings:
0

Energy Savings:
0

Do you like the savings?

NOTE: The results generated by this calculator are estimates only based on the information provided and selected by you. Watts does not guarantee that you will achieve the exact savings generated by this tool, as conditions at each property, including energy consumption and cost, can vary.

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.




Resort Turns to IntelliStation 2 for Improved Operations 

The Grandover Resort struggled with inconsistent hot water temperature and pressure that jeopardized guest satisfaction and lost the facility money in refunds. 

IS2-cs-thumb

  • Traditional TMVs couldn’t keep up with demand, leaving upper floors with weak pressure and tepid water temperatures
  • They installed the IntelliStation 2 and immediately restored nearly 6 pounds of pressure
  • Eliminating customer complaints, The Grandover improved guest comfort, reduced energy consumption, and lowered overall energy costs